<ArticleTitle>Climate and environmental impacts on power grids in Khuzestan province</ArticleTitle>
<VernacularTitle>Climate and environmental impacts on power grids in Khuzestan province</VernacularTitle>
			<FirstPage>305</FirstPage>
			<LastPage>317</LastPage>
			<ELocationID EIdType="pii">113840</ELocationID>
			
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Marzieh</FirstName>
					<LastName>Shahsavandi</LastName>
<Affiliation>Department of Climatology, Ahwaz Islamic Azad University, Ahvaz, Iran.</Affiliation>

</Author>
<Author>
					<FirstName>Jafar</FirstName>
					<LastName>Morshedi</LastName>
<Affiliation>Department of Climatology, Ahwaz Islamic Azad University, Ahvaz, Iran.</Affiliation>

</Author>
<Author>
					<FirstName>Ali Reza</FirstName>
					<LastName>Shakiba</LastName>
<Affiliation>Department of Climatology, Shahid Beheshti University, Tehran, Iran.</Affiliation>

</Author>
<Author>
					<FirstName>Manijeh</FirstName>
					<LastName>Zohourian Por Del</LastName>
<Affiliation>Department of Climatology, Ahwaz Islamic Azad University, Ahvaz, Iran.</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2018</Year>
					<Month>09</Month>
					<Day>05</Day>
				</PubDate>
			</History>
		    <Abstract>Abstract Although dust mite incidence has a long history in Khuzestan province, recent decades are one of the areas of interest especially in spring and summer, with negative consequences, which could lead to disruption of electricity systems, short life span, and short life span. Corrosion, fires, breakage of insulators, and numerous financial hints. Since maintenance of electricity lines is one of the most important factors in the sustainability of the electricity grid, however, because many of these lines are located in an open area, they are always subject to damage such as dust, sand, moisture, salt, materials. Are chemical and ... that, when combined with moisture, become out of orbit and unstable in the network, so given the systemic impact of microgravity and climatic parameters on power grid equipment, climatic information and the number of days of dust, shelf life, and measurements. From time to time electrical equipment (96 to 81) Meteorological organizations, environmental and electricity Akhzgrdyd eight synoptic stations were selected using density methods of salt deposits on the insulator surface ESDD soluble and insoluble precipitate another surface density and intensity of infection NSDD sitting insulators on electrical equipment analyzed. After analyzing the destructive effects of contaminants on the power grid, effective solutions were provided to minimize the damages caused by proper planning.</Abstract>
			<OtherAbstract Language="FA">Abstract Although dust mite incidence has a long history in Khuzestan province, recent decades are one of the areas of interest especially in spring and summer, with negative consequences, which could lead to disruption of electricity systems, short life span, and short life span. Corrosion, fires, breakage of insulators, and numerous financial hints. Since maintenance of electricity lines is one of the most important factors in the sustainability of the electricity grid, however, because many of these lines are located in an open area, they are always subject to damage such as dust, sand, moisture, salt, materials. Are chemical and ... that, when combined with moisture, become out of orbit and unstable in the network, so given the systemic impact of microgravity and climatic parameters on power grid equipment, climatic information and the number of days of dust, shelf life, and measurements. From time to time electrical equipment (96 to 81) Meteorological organizations, environmental and electricity Akhzgrdyd eight synoptic stations were selected using density methods of salt deposits on the insulator surface ESDD soluble and insoluble precipitate another surface density and intensity of infection NSDD sitting insulators on electrical equipment analyzed. After analyzing the destructive effects of contaminants on the power grid, effective solutions were provided to minimize the damages caused by proper planning.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Keywords: climate</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Dust</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Khuzestan</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">power grid</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">ESDD and NSDD</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.ims-jmas.net/article_113840_67cbb0c3de522033f7d8ee8edf447d2b.pdf</ArchiveCopySource>